and user-friendly remote control for milli-volt valve gas appliances.
The system can be manually turned on and off with the transmitter.
Always check with the home owner's manual of the appliance for
additional information, warnings regarding accessory installation
before connecting this remote control system.
Carefully inspect the contents for shipping damage. If any parts are
missing or damaged, immediately contact the dealer from whom you
purchased the kit. Do not attempt to install any part of the kit unless
all parts are in good condition. Please keep this manual for future
CONTENTS OF KIT
Description
Transmitter
Battery Alkaline AAA (for Transmitter)
Battery Alkaline AA (for receiver)
Receiver (Assembly) consists of:
Receiver Box
Slide Button–Black (On/RS/Off)
Wall Cover Plate–Black
Wall Cover Plate–White
Slide Button–White (On/RS/Off)
Battery Door–White
Plug-In Wiring Assembly – 22" Inches
Velcro (Loop and Hook)
Installation Instructions
#6 3/4" Screws, Zinc (for Wall Cover Plate)
#8 Screws (for fi replace system control covers)
FEATURES/SPECIFICATIONS
Battery Powered Transmitter and Receiver
Easy Access Front Battery Door
Pre-Programmed for Quick Installation
16 Security Codes
Quick Disconnect Wiring Assembly
Low battery indicators for Transmitter and Receiver
WARNING: Important Safety Information
• Read this manual thoroughly prior to installing, pro-
gramming or operating any remote control.
This remote control system is designed for use with a millivolt
or 24V gas valve system. Do not use this remote control sys-
tem on applications with voltages above 24 Volts AC/DC and
1 amp current.
This remote control system requires three (3) "AAA" and
four (4) "AA" alkaline batteries to power the transmitter and
Do not short (or jumper) across the gas valve terminals to
test the remote control installation. This could damage the
unit and void the warranty.
This remote control system should only be used as described
in this manual. Any other use is prohibited and will void the
50D0035 RCB.indd 1
50D0035 RCB.indd 1
WARNING: Turn appliance OFF and allow to cool before
installing or servicing. DO NOT connect 110-120 VAC
wiring to the milli-volt gas control valve. The remote
operator must be installed exactly as outlined in these
instructions. Read all instructions completely before attempting
installation. Follow instructions carefully during installation. Any
modifi cation of components will void the warranty and may cause
a fi re hazard.
WARNING: Turn appliance OFF (at the appliance or
remote receiver) if you are away from your house for a
long period of time.
INSTALLATIONS
The remote receiver may be wall mount-
ed or installed in the appliance per the
appliance homeowner's manual. Refer
to the Homeowner's Manual for special
installation instructions. If wall mounted, the
remote receiver must be installed in a junc-
tion box with cover plate provided. Failure to follow the installation
instructions found in the appropriate Homeowner's Manual will void
the warranty and may cause a fi re hazard.
Installing Batteries
The remote receiver uses four (4) "AA"
batteries. To install batteries:
1. Open the battery door by pressing the
two tabs located on the door.
2. Install the batteries as indicated in the
receiver cover.
3. Close the battery door until the door tab
snaps in place.
4. To install the receiver into a wall junction box, snap wall cover
plate to the receiver and install the receiver with the screws pro-
vided to the junction box.
5. Install slide switch back to the receiver stem.
6. The batteries should be replaced at least once every 6 months
or when the battery indicator fl ashes.
Installing Wire
This system comes with a 22 inch pre-assembled wire assembly.
Insert the white terminal to the back of the receiver. The terminal
wire block can only be installed one way. Do not force the terminal
plug onto the receiver.
Follow the homeowner's manual for connecting the two (2) 1/4"
female spade terminals to the milli-volt valve.
Connect to the two (2) 1/4" female spade wiring terminals.
Millivolt Valve
WARNING: Make sure that the wires do not contact the
appliances any place other than at the terminals. Expo-
sure to temperatures higher than 250ºF (105ºC) may
cause the receiver to malfunction or cause a fi re hazard.
Transmitter
Installing Batteries
The remote transmitter uses three (3) "AAA"
batteries. To install batteries:
1. Press down the battery door tab and lift up
and remove the battery door.
2. Install the batteries as indicated on transmit-
3. Close the battery door by snapping in place.
4. The batteries should be replaced at least
once every 6 months or when the battery
Back of Transmitter
indicator fl ashes.
WARNING: Do not use two (2) or more remote control
systems in the same area with the same dip switch
settings, as they will communicate with each other. This
may cause the appliances to malfunction.
Setting Privacy (DIP) Switch on Receiver and Transmitter
The remote receiver and transmitter privacy (DIP) switches are pre-
set at the factory. In the event of activation or interference from other
nearby transmissions, reset the code using the following procedure:
1. Slide the code switches on the transmitter or receiver to your
choice of ON or OFF position. Switches #1, #2, #3 and #4 are
preset to "ON" for both the transmitter and receiver.
2. The switches on the transmitter and receiver must match in order
for the system to work.
3. The system is now ready to operate.
Transmitter
Dip Switch (Default)
OPERATIONS
Transmitter
The RCB Remote Control provides the manual
fi replace on/off operation.
The transmitter will operate the remote receiver
from 1 foot to a maximum of 30 feet. The distance
is reduced when batteries are low or when the
receiver is inside a metal enclosure.
Initial Start-up
After initial power up the transmitter is ready for
Manual Mode
1. Press the ON button once to turn on the appli-
2. Press the OFF button to turn it off.
Low Battery Detection
When the battery voltage drops to a certain level, the LED on the
transmitter will blink until the battery expires. Change the battery be-
fore the battery is too weak for normal operation. TURN THE UNIT
OFF BEFORE REPLACING BATTERIES.
12/30/2014 9:08:36 AM
12/30/2014 9:08:36 AM
Basic on/off remote control (5 pages)
Basic on/off remote control (2 pages)
Thermostatic on/off, flame height adjustment and blower remote control 120 vac (12 pages)
Thermostatic on/off and blower remote control– 120vac (11 pages)
Thermostatic on/off remote control – 120vac (7 pages)
Manual on/off remote control with timer (7 pages)
Standard thermostatic on/off remote control (2 pages)
Variable flame remote control installation and operating instructions for concentric varitap, latchtap and maxtrolvalves (2 pages)
Thermostatic flame height adjustment remote for signature command system (2 pages)
Hi/lo remote control (7 pages)
Basic on/off remote control – 120vac (2 pages)